Dry Powder Fire Extinguishing System for Wind Power Applications

Keywords:

Telephone:

Detailed Description

Product Overview of Wind Power–Specific Dry Powder Fire Extinguishing Systems

I. Overview

FFX-AC F X/ZY The wind‑power‑specific dry‑powder fire‑extinguishing device (hereinafter referred to as the “extinguishing device”) is a next‑generation, highly efficient and environmentally friendly firefighting product. It is charged with… ABC Ultra-fine dry powder extinguishing agent is non-toxic and harmless, does not corrode protected materials, is non-irritating to human skin and respiratory tract, and delivers rapid, highly efficient fire suppression.

This fire suppression system features a simple structure, reliable performance, and convenient installation and maintenance. It can be used for total flooding in enclosed spaces as well as for localized suppression in open areas, making it an ideal automatic fire‑extinguishing solution for wind turbine nacelles.

Standards for the Production and Testing of Fire Extinguishing Equipment GA602-2013 Dry Powder Fire Extinguishing System

II. Scope of Application

1 . Firefighting A Class A fires: such as fires involving combustible solids like cotton, wood, hemp, paper, rubber, plastics, and tobacco.

2 . Firefighting B Class A fires: such as fires involving flammable liquids like crude oil, heavy oil, diesel, gasoline, and organic solvents, as well as combustible solids that can melt.

3 . Firefighting C Class C fires: such as fires involving flammable gases like coal gas, natural gas, acetylene, and others.

4 . Firefighting E Class A fires: such as fires involving energized equipment in computer rooms, substations, cable tunnels, cable trenches, and power compartments within urban utility tunnels.

This device is not suitable for extinguishing fires involving the following substances:

1. Chemical substances such as nitrocellulose, explosives, nitrogen oxides, and fluorine, which can undergo oxidation reactions even in the absence of air, together with oxidizing agents;

2. Reactive metals such as potassium, sodium, magnesium, titanium, and zirconium, as well as their hydrides.

III. Composition of the Fire Extinguishing System

The fire-extinguishing device is an integrated unit comprising ultra-fine dry powder extinguishing agent, an electric initiator, a solid‑gas conversion agent, a pressure‑rated steel housing, a six‑pronged nozzle, an aluminum diaphragm, and a mounting bracket.

  4. Model and Main Performance Parameters

1 , Model and Main Performance Parameters Table ( 1 )

Specification and Model

FFX-ACT3-ZY

FFX-ACT5-ZY

FFX-ACT8-ZY

Fire extinguishing agent quantity (kg)

3

5

8

Protected space (m³)

25

42

67

Class B fire extinguishing rating (B)

55B

55B

70B

Class A fire extinguishing rating (A)

1A

2A

3A

Spraying residual rate (%)

≤5

Spraying time (s)

≤5

Service life (years)

10

DC operating voltage (V)

24

Safe current (mA)

≤150

Starting current (mA)

≥1A

Applicable Temperature Range (°C)

-50~+90

V. Operating Principle

1 , Fire-extinguishing principle

When the fire suppression system receives an activation signal, the solid‑gas conversion agent is triggered, causing the gas inside the container to expand rapidly and the internal pressure to rise. This pressure ruptures the nozzle diaphragm, propelling an ultrafine dry powder into the protected area, where it quickly disperses in all directions, establishing a total flooding extinguishing effect. Under the continuous physical and chemical action of the ultrafine dry powder, the flames are extinguished.

 

2、 Fire suppression system activation methods

The device is simple and reliable to operate, offering two control modes: manual and system‑interlocked.

( 1 ) Manual start

When the fire suppression controller is set to the “Manual” position, the fire suppression system operates in manual mode. In the event of a fire in the protected area, manually pressing the start button on the fire suppression controller or on the manual control panel will activate the system to discharge the extinguishing agent and suppress the fire.

After the fire‑extinguishing device’s initiating mechanism is powered on, it activates the impact mechanism, which shatters the glass bulb and opens the nozzle to discharge the extinguishing agent, thereby suppressing the fire.

After the fire alarm control panel issues a start command, or after the start button is manually pressed, during the set delay period… 30s During this period, if personnel determine that no fire has occurred or that the fire has already been extinguished, they may press the emergency stop button to halt the activation of the fire suppression system.

( 2 ) System Integration (Automatic Startup)

When the fire suppression controller is set to the “Automatic” mode, the fire suppression system operates in automatic control. Upon detection of a fire in the protected area, the controller, having confirmed the occurrence of a fire, automatically activates the fire suppression system to discharge the extinguishing agent and initiate fire suppression.

After the fire‑extinguishing system’s initiating device is powered on, it activates the impact mechanism, which shatters the glass bulb and opens the spray nozzle to discharge the extinguishing agent, thereby suppressing the fire.

VI. Installation of Fire Extinguishing Systems

( 1 ) Installation and Operation Instructions for Wind Power–Specific Dry Powder Fire Extinguishing Systems

1 • During product transportation, handling, and storage, dropping and rough loading/unloading are strictly prohibited.

2 The fire suppression system must not be serviced while energized. If maintenance is required, the system’s power supply must be disconnected, and the system’s activation circuit must be shorted.

3 , The safety current for the electrical start-up of the fire-extinguishing system shall not exceed 150m A ;

4 , Task testing is prohibited without the authorization of the manufacturer’s representative;

5 , Verify that the internal supply components in the inspection report are complete;

6 , Check whether the device leads are shorted;

( 2 ) Installation Method for Wind Power–Specific Dry Powder Fire Extinguishing Systems

1. The installation methods for fire suppression systems are as follows:

 

 

 

 

 

 

 

 

 

 

Insert the expansion screw ( M10 ) Secure the fixture to the precast concrete slab above the protected area, then insert the mounting base of the fire suppression device into the mounting bracket and fasten it with screws, as shown in the figure.

7. Inspection and Maintenance of Fire Extinguishing Systems

1. The user unit shall establish a maintenance management system and assign dedicated personnel to conduct regular inspections.

2. Fire extinguishing systems shall be inspected at least once every six months. Once a fire extinguishing system has been activated, it must be replaced.

3 The extinguishing agent used during refilling must be ABC Ultra-fine dry powder extinguishing agent, and shall comply with GB4066 -2017 Requirements.

4.   Maintenance of fire-extinguishing equipment must be performed by a specialized manufacturer approved by the public security fire supervision authority.

5.   Under normal conditions, the service life of the fire suppression system is 10 Year.

 

 

FAQ for Wind Power‑Specific Dry Powder Fire Extinguishing Systems
Q: What are the primary application scenarios for wind‑farm‑specific dry‑powder fire‑extinguishing systems?
A: Specifically designed for wind turbine generators, it is suitable for use in confined, high‑altitude, enclosed spaces such as nacelles, hubs, tower control cabinets, and converter cabinets. It can effectively extinguish common electrical fires, mechanical‑friction fires, and Class A, B, and C fires, including energized‑equipment fires.
Q: What is the difference between a wind‑power‑specific fire‑extinguishing system and a standard dry‑powder fire‑extinguishing system?
A: Custom-designed for the high-altitude, turbulent, low-temperature, high-humidity, and salt-spray environments typical of wind power applications, it features seismic resistance, vibration damping, extreme temperature tolerance, and resistance to salt‑spray corrosion. It is well‑suited to the long‑term vibration conditions of wind turbines and offers significantly superior stability compared with standard civilian dry‑powder systems.
Q: What startup modes are available for the wind‑power dry‑powder unit?
A: Supports temperature‑controlled, heat‑sensing automatic activation and can be integrated with wind‑turbine fire detection systems to enable electrically controlled, interlocked start-up. Certain models are equipped with an emergency manual start function, meeting the fire‑suppression requirements of unattended wind turbines.
Q: Will the device’s installation in the wind turbine nacelle or tower be affected by vibration, leading to false activation?
A: No. The product features an earthquake‑resistant, vibration‑damping structural design that accommodates the continuous vibrations and shaking typical of fan operation, effectively preventing malfunctions such as unintended spraying or startup and ensuring safe, reliable operation.
Q: Can it withstand extreme temperatures and harsh outdoor conditions?
A: Yes. The wind‑power‑specific device covers the extreme outdoor operating conditions of wind turbines, offering excellent resistance to both low and high temperatures, as well as superior performance against moisture, salt spray, and aging, making it suitable for the harsh environments of onshore and offshore wind farms.
Q: Will the device damage the fan’s precision equipment after discharge?
A: The specialized ultra-fine dry powder features fine particles, rapid extinguishing performance, and strong flame‑retardant properties. Although a small amount of residual dust remains, it is less corrosive than conventional dry powder, making it well suited for fire protection of fan‑driven machinery and electrical equipment; post‑fire cleanup is straightforward.
Q: Is routine maintenance of high-altitude fan equipment convenient?
A: The device features a simple structure, eliminating the need for frequent maintenance. Routine operations are limited to visual inspections and pressure checks (for pressurized models), with no complex upkeep required. This design aligns with the challenges of high‑altitude wind turbine maintenance, thereby reducing operational and maintenance costs.
Q: Can the fire suppression system be reused after it has been discharged?
A: This is a single-use fire suppression device; once the discharge mechanism is activated, it becomes completely inoperable. It cannot be reused or refilled on-site and must be replaced entirely with a new unit.
Q: How long is the device’s shelf life, and is regular hydrostatic pressure testing required?
A: Wind‑power‑specific dry‑powder extinguishing agents have a long shelf life and are suitable for prolonged outdoor storage; non‑pressurized models do not require water‑pressure testing, while pressurized models undergo regular pressure inspections in accordance with fire‑safety regulations and are replaced entirely upon expiration.
Q: Does this device meet the fire safety acceptance requirements for wind power projects?
A: The product complies with fire‑safety design standards for the wind power industry, holds full testing qualifications and corresponding test reports, is compatible with fire‑safety acceptance procedures for both onshore and offshore wind turbines, and can successfully pass the project’s overall fire‑safety completion inspection.
 